AC Electronic Switches - CUSTOMISED. NO DERATING REQUIRED.

Current Rating : ANY CURRENT RATING [2Amp. to 5,000Amp.].

Switching/Time :
   (1) Zero Voltage / Max.9 msec.
   (2) Random Switching (Phase Control) / Max. 100 micro Sec.

Life   : INFINITE.


Products :
 1) Solid State Relays : (for ZERO Voltage / Random Switchings)
5Amp./230V Zero Turn ON SSR.
<A> PCB Mounting type Upto 5Amp.[230V / 415V].
    These SSRs can be Mounted on PCB as it has PIN Teminations. Upon request we also provide these SSRs on our PCBs (1/2/3 Phase) along with RC / Snubbers of required raing (of the acutal LOAD) and also Terminals for input. Needs control of 12-24Vdc.


<B> Screw Type Terminals from :

1) 5A to 8A [230/415V]8Amp./230V Phase Control SSR.
Usable upto 8Amps., 230 or 415Vac for both Zero Crossing as well as Random switching.
Can be mounted on a Heat Sink with C Bracket terminals are of PUT2.5 Type. Needs control of 12-24Vdc.



2) 10A. to 20A. [230/415Vac]12Amp./230V Zero Turn ON SSR.
Needs control of 12-24Vdc. There are 2 Types : 1 - Plastic Base (only for 8Amps.) &
                                                                           
2 - Aluminium Base



<C> High Current 55Amp./480Vac.

This SSR can take Load Current upto 32 Amperes (with Heat sink of 259mm length).

Can also be mounted on Din Rail Clamp.



2) Drivers : used to drive/fire THYRISTORS upto 5KA.of our make are used to DRIVE THYRISTORS (SCRs) of any current rating upto 5,000 Amperes CURRENT for switching ON Transformers (SECONDARY CURRENT =50KA), is used to Test MCB/MCCB/ACB on We supply various models depending on the load, its Current Capacity, Voltage, Switching frequency (no. of operations per minute), etc...
     We have supplied such a system to L&T Switchgear Division situated at POWAI, MUMBAI, where our drivers are used to drive SCRs of 2500Amp.(LOAD) in a FULLY COMPUTERISED TEST BENCH.
The above system is working faultlessly for more than 2 years now .

Driver Type For Switching at

Used for Current Rating
(Actual Load Rating)
(

2XC (Z)
Zero Voltage
Upto 70 Amps.(230 / 415Vac)
2XC-HC (Z)
Zero Voltage
Greater Than 70Amps
2XT (PHC)
Phase Angle/
Random Switching
Upto 70Amps.
2XT-HC (PHC)
Phase Angle/
Random Switching
Greater Than 70 Amps.

3) Contactor :  We also Design and Manuafcture, Supply SOLID STATE CONTACTORS as Retrofit Unit for 2 Phase Spot/Resistance Welding M/cs. Also 3Phase units for Furnaces and other Applications.
                                                                                  RETROFIT UNIT
Current Rating :- Right from 4 Amperes to 3,000 Amperes.

Benifits :
     1) Good Welding Quality.
     2) No Breakdown Time.
     3) Saving in power BILLS.


4) AC Power Control Modules (0 - 10V or 4 to 20mA)
Used to control the Output power as the case may be.

5) Transient Voltage Suppression (See Details).